Skip to main content
Back To Top Top Back To Top
This website publishes administrative rules on their effective dates, as designated by the adopting state agencies, colleges, and universities.

Rule 3745-113-03 | Standards for architectural and industrial maintenance (AIM) coatings.

 

(A) On or after the effective date specified, any person subject to this chapter in accordance with rule 3745-113-02 of the Administrative Code shall ensure that the AIM coatings meet the following limits:

(1) VOC content limits.

Limits are expressed as VOC content, thinned to the manufacturer's maximum thinning recommendation, excluding any colorant added to tint bases.

Coating TypeLimit (grams/liter)Limit (pounds/gallon)Limit (grams/liter)Limit (pounds/gallon)
Effective January 1, 2009 until December 31, 2023Effective January 1, 2009 until December 31, 2023Effective January 1, 2024Effective January 1, 2024
Flat coatings1000.83500.42
Non-flat coatings1501.251000.83
Non-flat-high-gloss coatings2502.081501.25
Specialty coatings:
Aluminum roofN/AN/A4503.75
Antenna coatings5304.42N/AN/A
Anti-fouling coatings4003.33N/AN/A
Basement specialty coatingsN/AN/A4003.33
Bituminous roof coatings3002.502702.25
Bituminous roof primers3502.923502.92
Bond breakers3502.923502.92
Calcimine recoaters4753.964753.96
Clear wood coatings:
Clear brushing lacquers6805.67N/AN/A
Lacquers, including clear lacquer sanding sealers5504.59N/AN/A
Sanding sealers, excluding clear lacquers3502.92N/AN/A
Varnishes other than conversion varnishes3502.92N/AN/A
Concrete curing compounds3502.923502.92
Concrete/masonry sealerN/AN/A1000.83
Concrete surface retarders7806.507806.50
Conjugated oil varnish4503.754503.75
Conversion varnish7256.047256.04
Driveway sealersN/AN/A500.42
Dry fog coatings4003.331501.25
Faux finishing coatings3502.923502.92
Fire-resistive coatings3502.923502.92
Fire-retardant coatings:
Clear6505.42N/AN/A
Opaque3502.92N/AN/A
Floor coatings2502.081000.83
Flow coatings4203.50N/AN/A
Form-release compounds2502.082502.08
Graphic arts coatings (sign paints)5004.175004.17
High-temperature coatings4203.504203.50
Impacted immersion coatings7806.507806.50
Industrial maintenance coatings3402.832502.08
Low-solids coatings1201.001201.00
Magnesite cement coatings4503.754503.75
Mastic texture coatings3002.501000.83
Metallic pigmented coatings5004.175004.17
Multi-color coatings2502.082502.08
Nuclear coatings4503.754503.75
Pre-treatment wash primers4203.504203.50
Primers, sealers, and undercoaters2001.671000.83
Quick-dry enamels2502.08N/AN/A
Quick-dry primers, sealers and undercoaters2001.67N/AN/A
Reactive penetrating sealerN/AN/A3502.92
Reactive penetrating carbonate stone sealerN/AN/A5004.17
Recycled coatings2502.082502.08
Roof coatings2502.082502.08
Rust preventive coatings4003.332502.08
Shellacs:
Clear7306.097306.09
Opaque5504.595504.59
Specialty primers, sealers and undercoaters3502.921000.83
Stains2502.082502.08
Stone consolidantN/AN/A4503.75
Swimming pool coatings3402.833402.83
Swimming pool repair & maintenance coatings3402.83N/AN/A
Temperature-indicator Safety coatings5504.59N/AN/A
Thermoplastic rubber coatings and mastics5504.595504.59
Traffic marking coatings1501.251000.83
Tub and tile refinishN/AN/A4203.50
Waterproofing membranesN/AN/A2502.08
Waterproofing sealers2502.08N/AN/A
Waterproofing concrete/masonry sealers4003.33N/AN/A
Wood coatingsN/AN/A2752.29
Wood preservatives3502.923502.92
Zinc-rich primerN/AN/A3402.83

Conversion factor: one pound VOC per gallon (US) = 119.95 grams per liter.

(2) Most restrictive VOC limit.

If a coating is recommended for use in more than one of the specialty coating categories listed in the table in paragraph (A) of this rule, the most restrictive (or lowest) VOC content limit applies. This requirement applies to: usage recommendations that appear anywhere on the coating container, anywhere on any label or sticker affixed to the container, or in any sales, advertising, or technical literature supplied by a manufacturer or anyone acting on their behalf.

(a) Effective for products manufactured before January 1, 2024, this provision does not apply to the following coating categories:

(i) Lacquer coatings (including lacquer sanding sealers).

(ii) Metallic pigmented coatings.

(iii) Shellacs.

(iv) Fire-retardant coatings.

(v) Pretreatment wash primers.

(vi) Industrial maintenance coatings.

(vii) Low-solids coatings.

(viii) Wood preservatives.

(ix) High-temperature coatings.

(x) Temperature-indicator safety coatings.

(xi) Antenna coatings.

(xii) Antifouling coatings.

(xiii) Flow coatings.

(xiv) Bituminous roof primers.

(xv) Specialty primers, sealers, and undercoaters.

(xvi) Thermoplastic rubber coatings and mastics.

(xvii) Calcimine recoaters.

(xviii) Impacted immersion coatings.

(xix) Nuclear coatings.

(b) Effective for products manufactured on or after January 1, 2024, this provision does not apply to the following coating categories:

(i) Aluminum roof coatings.

(ii) Bituminous roof primers.

(iii) High temperature coatings.

(iv) Industrial maintenance coatings.

(v) Low-solids coatings.

(vi) Metallic pigmented coatings.

(vii) Pretreatment wash primers.

(viii) Shellacs.

(ix) Specialty primers, sealers, and undercoaters.

(x) Wood coatings.

(xi) Wood preservatives.

(xii) Zinc-rich primers.

(xiii) Calcimine recoaters.

(xiv) Impacted immersion coatings.

(xv) Nuclear coatings.

(xvi) Thermoplastic rubber coatings and mastic.

(xvii) Concrete surface retarders.

(3) Sell-through of coatings.

A coating manufactured prior to the effective date specified for that coating in the table in paragraph (A) of this rule, and that complied with the standards in effect at the time the coating was manufactured, may be sold, supplied, or offered for sale for up to three years after the specified effective date. In addition, a coating manufactured before the effective date specified for that coating in the table in paragraph (A) of this rule may be applied at any time, both before and after the specified effective date, so long as the coating complied with the standards in effect at the time the coating was manufactured. This paragraph does not apply to any coating that does not display the date or date code required by rule 3745-113-04 of the Administrative Code.

(B) Painting practices.

All AIM coating containers used to apply the contents therein to a surface directly from the container by pouring, siphoning, brushing, rolling, padding, ragging, or other means, shall be closed when not in use. These AIM coatings containers include, but are not limited to, drums, buckets, cans, pails, trays, or other application containers. Containers of any VOC-containing materials used for thinning and cleanup shall also be closed when not in use.

(C) Thinning.

No person who applies or solicits the application of any AIM coating shall apply a coating that is thinned to exceed the applicable VOC limit specified in the table of paragraph (A)(3) of this rule.

(D) Rust preventive coatings.

No person shall apply or solicit the application of any rust preventive coating for industrial use, manufactured before January 1, 2024, unless such a rust preventive coating complies with the industrial maintenance coating VOC limit specified in the table in paragraph (A) of this rule. No person shall sell or offer for sale any rust preventive coating for application to any nonmetallic substrate, nor shall any person apply a rust preventive coating to any nonmetallic substrate.

(E) Coatings not listed in the table of paragraph (A) of this rule.

For any coating that does not meet any of the definitions for the specialty coatings categories listed in the table of paragraph (A) of this rule, the VOC content limit is determined by classifying the coating as a flat coating, non-flat coating, or non-flat-high-gloss coating as defined in rule 3745-113-01 of the Administrative Code and the corresponding flat or non-flat or non-flat-high-gloss coating limit in the table in paragraph (A) of this rule applies.

(F) New categories.

Prior to January 1, 2024, any coating that meets the definition in rule 3745-113-01 of the Administrative Code for a coating category listed in the table in paragraph (A) of this rule, and complies with the applicable VOC limit in the table in paragraph (A) of this rule and reporting requirements, is considered in compliance with this rule.

Last updated December 16, 2022 at 8:42 AM

Supplemental Information

Authorized By: 3704.03(E)
Amplifies: 3704.03(A), 3704.03(E)
Five Year Review Date: 12/16/2027
Prior Effective Dates: 9/21/2007, 10/18/2013, 2/16/2019